![](https://www.globalindustrialsupplies.eu/wp-content/uploads/2016/09/baldor-gallery-5-200x200.jpg)
216
Inverter/Vector Motors & Controls
Farm Duty
Motors
Definite Purpose
Motors
Unit Handling Motors
Brake Motors
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
Product Highlights:
The VS1MXS is a feature rich V/Hz & Sensorless
Vector product targeted at the 600V market and harsh duty applications.
Applications:
Variable torque, constant torque or constant horsepower
applications. New installations, replacements and original equipment
manufactures (OEM).
Features:
V/Hz and Sensorless Vector Control with peak overload
capacity of 175% and P±D capability. Flexible mounting options with ±P55
(NEMA 12) enclosure as standard. ±ntegral keypad, operator interface and
local speed control.
Basic setup parameter list and advanced software
settings. Built-in braking transistor allows connection to remote braking
resistor for enhanced performance needs. Power ratings up to 7.5 HP at
600V, pluggable ±/O terminal strip.
VS1MXS
600V Harsh Duty
AC Micro Drive
1 thru 7.5 Hp
500-600 VAC
3 Phase - 50/60 Hz
Performance Features
Control Modes
V/Hz & Sensorless Vector Control
Operator Interface Module
Integral Drive Mounted; basic start/stop, forward/reverse and speed control
Display Lines
6-Character LED Display
Programmable Preset Speeds
Eight
Analog Output: One
0-10VDC or 20mA
Auto Restart
Yes -- Up to 5 attempts
Frequency Avoidance
One Band
Fault History
Last 4 Faults
Digital Inputs: Four
Two programmable digital inputs, two user selectable analog/digital inputs
Digital Inputs Type
Pull-Up
DrIv
e Specifications
Analog Inputs: Two
One bi-polar and one 0-10VDC, 0 to 20mA or 4 to 20mA
Relay Output: One
Built-in Form C Relay, normally open contact
Analog Output/Digital: One
0-10 VDC: One Analog Usable for Meter (Freq., Current, Voltage) or Digital Output
Maximum Load:
7.5 HP @ 600 VAC
Overload Capacity
Drive Output 150% for one minute and 175% for 2 seconds
Input Voltage Ranges
500 - 600VAC
Input Voltage Tolerance
10% / -10%
Rated Input Frequency
50-60Hz (³5%)
Carrier Frequency
4-32 kHz (8 kHz default)
Operating Temperature
-10° to 50°C
Snubber (Dynamic Braking)
Built-in Transistor
Dynamic Braking External
Up to 150% Dynamic Braking with appropriately sized resistor
DC Injection Braking
Included
Volts/Hz
Linear V/Hz, Energy Optimization Function
Sensorless Vector
Full Sensorless Vector Control with Autotune and motor model
Frequency Control Range
0 - 2000Hz
Accel/Decel:
Independently adjustable accel. & decel. ramps
Keypad Speed Control
Yes
Sink/Source Inputs
Selectable, 24 VDC Logic
Electronic Overload Trip
Electronic Motor Overload Inverse 150% for 1 minute or 175% for 2 seconds
Communications
Built-in MODBUS-RTU (RS-485) Communications, RJ11 connection
PID Control
Built-in with sleep/wake function
Protective Features
Under Voltage
Level Depends on Voltage Class (600V)
Output Short Circuit
Phase-to-Phase on Drive Output
Over Temperature
Heatsink Monitor
DC Bus Overvoltage
DC Bus Level Trip
Drive Overload
Exceed Drive rating of 150% for One Minute or 175% for 2 seconds
Over Current
Over-current/short-Circuit protection
Output Phase
Trips on open Output Phase
Loss of Reference
Trips on Loss of Speed Command Signal
Communication Error
Detects a communication error (fault)
Agency Certifications
UL, cUL, CE, CCC, C-tick
Service Conditions
Altitude
1,000 m (3,300 ft.) Maximum
Ambient Temperature
-10°C to 50°C
Storage Temperature:
-20°C to 60°C
Relative Humidity
10% to 90%, non-condensing
Intermittent Overload
150% overload capacity for up to 1 minute