BALDOR
164
IEC Frame Motors
Farm Duty
Motors
Definite Purpose
Motors
Unit Handling
Motors
Brake Motors
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Inverter/Vector
Motors & Controls
DC Motors
and Controls
Soft Start & Dynamic
Brakes
Metric IEC
Frame Motors,
Three Phase, 50 Hz,
230/400 and 400 Volts,
B5 Flange
.12 thru 55 kW (.16-75 Hp)
IEC D63D thru D250D
Applications:
Pumps, compressors, fans, conveyors, and other general purpose
three phase applications r
equiring ±EC metric B5 lange mount repLacements.
(a)
See notes on inside back lap.
Motors shown as “60 Hz Use in US” are compLiant with U.S. DOE and Canadian NRCan efIciency requirements. These motors are usabLe on the 400 V, 50 Hz connection
for use at 460 V, 60 Hz (230 V, 60 Hz use is not possibLe).
kW/Hp
RPM
±EC
Frame
Catalog
Number
LIst
PrIce
Mult.
Sym.
“L”
DIm. (In)
Aprx.
Wt. (lb)
Full Load
EficIency
Voltage
FLA
@ 400V
60 Hz Use
In US
Notes
(a)
.12/.16
1500
D63
MVM06124D-AP
291
M
8.43
9
65.5
230/400
0.5
Yes
11, 25
.18/.25
3000
D63
MVM06182D-AP
284
M
8.43
9
75
230/400
0.6
Yes
11, 25
1500
D63
MVM06184D-AP
294
M
8.43
10
67.3
230/400
0.6
Yes
11, 25
.25/.33
3000
D63
MVM06252D-AP
289
M
8.43
10
78.6
230/400
0.7
Yes
11, 25
1500
D71
MVM07254D-AP
308
M
9.45
11
65.1
230/400
0.7
Yes
11, 25
.37/.5
3000
D71
MVM07372D-AP
315
M
9.45
11
71.6
230/400
1
Yes
11, 25
1500
D71
MVM07374D-AP
341
M
9.45
11
69.7
230/400
1
Yes
11, 25
.55/.75
3000
D71
MVM07552D-AP
348
M
9.45
11
78.4
230/400
1.3
Yes
11, 25
1500
D80
MVM08554D-AP
372
M
10.45
19
74.1
230/400
1.4
Yes
11, 25
.75/1
3000
D80
MVM08752D-AP
413
M
10.45
23
80.3
230/400
1.8
Yes
11, 25
1500
D80
MVM08754D-AP
420
M
10.45
20
79.8
230/400
1.7
Yes
11, 25
1.1/1.5
3000
D80
MVM08112D-AP
444
M
10.45
24
80.9
230/400
2.5
Yes
11, 25
1500
D90
MVM09114D-AP
456
M1
12.19
35
83.7
230/400
2.4
No
11, 25
1.5/2
3000
D90
MVM09152D-AP
494
M1
12.19
35
84.1
230/400
2.9
No
11, 25
1500
D90
MVM09154D-AP
546
M1
13.05
35
84.2
230/400
3.3
No
11, 25
2.2/3
3000
D90
MVM09222D-AP
612
M1
12.19
35
84.6
230/400
4.4
No
11, 25
1500
D100
MVM10224D-AP
648
M1
13.82
55
86.4
230/400
4.6
Yes
11, 25
3/4
3000
D100
MVM10032D-AP
727
M1
13.82
55
86.4
230/400
5.8
Yes
11, 25
1500
D100
MVM10034D-AP
774
M1
13.82
64
85.7
230/400
6.3
Yes
11, 25
4/5.3
3000
D112
MVM11042D-AP
869
M1
15.47
66
86.1
230/400
7.6
No
11, 25
1500
D112
MVM11044D-AP
903
M1
15.47
75
86.7
230/400
8.8
No
11, 25
5.5/7.5
1500
D132
MVM13554D-AP
1,153
M1
17.60
106
89
400/690
11.2
No
11, 25
5.5/7.5
1500
D132
MVM13754D-AP
1,455
M1
17.60
130
89.1
400/690
15.3
No
11, 25
11/15
1500
D160
MVM16114D-AP
1,995
M1
22.99
234
91
400/690
20.9
Yes
11, 25
15/20
1500
D160
MVM16154D-AP
2,540
M1
26.81
273
91
400/690
28.5
Yes
11, 25
18.5/22
1500
D180
MVM18184D-AP
2,938
M1
28.58
338
91
400/690
34.5
Yes
11, 25
22/30
1500
D180
MVM18224D-AP
3,480
M1
28.58
375
91
400/690
40.9
Yes
11, 25
30/40
1500
D200
MVM20304D-AP
4,492
M1
32.32
503
93.2
400/690
55.3
Yes
11, 25
37/50
1500
D225
MVM22374D-AP
5,430
M1
34.65
547
93.4
400/690
68
Yes
11, 25
45/60
1500
D225
MVM22454D-AP
6,541
M1
34.65
620
93.9
400/690
81.3
Yes
11, 25
55/75
1500
D250
MVM25554D-AP
7,923
M1
34.80
772
89.5
400/690
98.9
Yes
11, 25
Features:
ABB Process Performance (severe duty) ±P55 construction. ALuminum
frame and endpLates. ±E2 efIciency per ±EC 60034-30; 6 post terminaL bLock with
230D/400Y or 400D/690Y voLt connections at 50 Hz.
CLass F insuLated motors
that operates within CLass “B” temperature Limits. 1.0 Service Factor. Some ratings
are marked with DOE compLiance number for use on 460 voLt, 60 Hz for use in US.
SuitabLe for mounting in any position. ±nverter-ready.