ABB
40
ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 12-2007
1
HV Process performance cast iron motors - Variant codes
P
=
New manufacture only.
1)
Certain variant codes cannot be used simultaneously.
R
=
On request.
Code
Variant
Motor size
1)
315
355
400
450
Balancing
423
Balanced without key
P
P
P
P
424
Full key balancing.
P
P
P
P
Bearings and lubrication
036
Transport lock for bearings.
P
P
P
P
037
Roller bearing at D-end.
P
P
P
P
107
Pt100 2-wire in bearings.
P
P
P
P
178
Stainless steel/acid proof bolts.
P
P
P
P
398
Motor designed for ambient temperature -20°C to -40°C
P
P
P
P
651
Dial type thermometers (2 pcs) for bearings, without contacts
P
P
P
P
652
Dial type thermometers (2 pcs) for bearings, with contacts
P
P
P
P
654
Provision for vibration sensors (M8x1)
P
P
P
P
Cooling system
044
Unidirectional fan, clockwise seen from D-end.
NA
P
P
P
045
Unidirectional fan, counter clockwise seen from D-end.
NA
P
P
P
068
Metal fan.
P
P
P
P
Coupling
035
Assembly of customer supplied coupling-half.
P
P
P
P
Drain holes
065
Plugged existing drain holes.
P
P
P
P
448
Draining holes with metal plugs.
P
P
P
P
Hazardous environments
See catalogue “Motors for Hazardous Environments”, BU/Ex-motors EN, for details.
Heating elements
450
Heating element, 100-120 V.
P
P
P
P
451
Heating element, 200-240 V.
P
P
P
P
Painting
114
Special paint colour, standard grade.
P
P
P
P
754
Painting system C5M - Coastal and offshore areas with high salinity.
P
P
P
P
Protection
005
Metal protective roof, vertical motor, shaft down.
P
P
P
P
158
Degree of protection IP 65.
P
P
P
P
403
Degree of protection IP 56.
P
P
P
P
Rating & instruction plates
002
Restamping output and voltage, continuous duty.
P
P
P
P
135
Mounting of additional identification plate, stainless
P
P
P
P
Standards and regulations
010
Fulfilling CSA Safety Certificate.
P
P
P
P
778
GOST Export/Import Certificate (Russia).
P
P
P
P
Stator winding temperature sensors
653
Pt-100 (12 pcs) inside stator slots
P
P
P
P
Terminal box
021
Terminal box LHS (seen from D-end).
P
P
P
P
447
Top mounted separate auxiliary box for heating elements.
P
P
P
P
655
No terminal box, three (3) leads out 1.5 m (5 ft)
P
P
P
P
656
No terminal box, six (6) leads out 1.5 m (5 ft)
P
P
P
P
750
Star point terminal box.
P
P
P
P
Testing
Routine test report included as standard.
146
Type test with report for motor from specific delivery patch.
P
P
P
P
147
Type test with report for motor from specific delivery patch, customer witnessed.
P
P
P
P
762
Noise level test.
P
P
P
P
Variable speed drives
701
Insulated bearing at N-end.
P
P
P
P
Foundation and installation
Foundation studs
P
P
P
P
Sole plates without anchor bolts
P
P
P
P
Sole plates with anchor bolts
P
P
P
P
Slide rails for belt drives
P
P
P
P
NA =