Efficiency
Power factor
Current
Speed
r/min
Full
load
100%
3/4
load
75%
Full
load
100%
3/4
load
75%
I
N
A
I
S
I
N
I
0
A
Output
kW
Motor type
Product
code
1)
315LK:
The given values of load inertia assume three starts from
cold and two starts from warm conditions in succession against
quadratic load torque with 90% of the rated torque at the rated
speed and at 80% of the rated voltage.
355LK:
The given values of load inertia assume two starts from
cold and one start from warm conditions in succession against
quadratic load torque with 80% of the rated torque at the rated
speed and at 80% of the rated voltage.
400LK, 450L:
The given values of load inertia assume two starts
from cold and one start from warm conditions in succession
against quadratic load torque with 75% of the rated torque at the
rated speed and at 80% of the rated voltage.
To check validity against other starting requirements, contact ABB.
2)
315LK:
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90% of
the rated torque at the rated speed and at rated voltage.
355LK:
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 80% of
the rated torque at the rated speed and at rated voltage.
400LK, 450L:
Starting time with given values of the load inertia
from cold condition in succession against quadratic load torque
with 75% of the rated torque at the rated speed and at rated
voltage.
3)
The sound pressure levels are presented at no-load. The magnetic
noise level of 2- and 4-pole motors is typically low compared
to the fan noise, resulting no increase in the noise level on-load.
The variation and measuring tolerance of the figures is +3 dB(A).
The bullet in the product code indicates choice of mounting arrangement (see ordering information page).
HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B, ambient temperature 40°C
1500 r/min = 4 poles
3300 V
50 Hz
132
M3BM
315 LKA
3GBM
312 810
-•
RB
1486
94.8
94.7
0.85
0.83
29
5.3
10
140
M3BM
315 LKB
3GBM
312 820
-•
RB
1486
95.0
94.9
0.85
0.83
30
5.4
10
160
M3BM
315 LKC
3GBM
312 830
-•
RB
1485
95.1
95.1
0.85
0.83
34
5.2
11
180
M3BM
355 LKA
3GBM
352 810
-•
RB
1490
95.2
94.9
0.83
0.79
40
5.4
15
200
M3BM
355 LKB
3GBM
352 820
-•
RB
1490
95.5
95.2
0.84
0.81
44
5.3
15
224
M3BM
355 LKC
3GBM
352 830
-•
RB
1490
95.7
95.5
0.84
0.82
49
5.3
16
250
M3BM
355 LKD
3GBM
352 840
-•
RB
1490
95.9
95.7
0.84
0.82
54
5.4
18
280
M3BM
355 LKE
3GBM
352 850
-•
RB
1490
95.9
95.8
0.85
0.82
60
5.2
20
315
M3BM
355 LKF
3GBM
352 860
-•
RB
1490
96.1
96.0
0.85
0.83
68
5.4
22
335
M3BM
355 LKG
3GBM
352 870
-•
RB
1490
96.3
96.2
0.85
0.83
72
5.7
23
355
M3BM
400 LKA
3GBM
402 810
-•
RB
1489
96.1
96.1
0.85
0.83
76
5.0
23
400
M3BM
400 LKB
3GBM
402 820
-•
RB
1490
96.4
96.3
0.85
0.83
86
5.3
27
450
M3BM
400 LKC
3GBM
402 830
-•
RB
1490
96.6
96.5
0.86
0.84
95
5.4
28
500
M3BM
400 LKD
3GBM
402 840
-•
RB
1490
96.7
96.7
0.86
0.85
105
5.5
29
560
M3BM
450 LA
3GBM
452 510
-•
RB
1491
96.6
96.5
0.86
0.86
117
5.4
31
600
M3BM
450 LB
3GBM
452 520
-•
RB
1491
96.7
96.6
0.87
0.86
125
5.4
32
1500 r/min = 4 poles
6600 V
50 Hz
224
M3BM
355 LKA
3GBM
352 810
-•
SB
1487
95.5
95.4
0.84
0.82
24
5.4
8
250
M3BM
355 LKB
3GBM
352 820
-•
SB
1487
95.7
95.7
0.85
0.82
27
5.4
9
280
M3BM
400 LKA
3GBM
402 810
-•
SB
1491
95.5
95.3
0.84
0.81
31
5.4
11
315
M3BM
400 LKB
3GBM
402 820
-•
SB
1491
95.7
95.6
0.85
0.82
34
5.3
11
355
M3BM
400 LKC
3GBM
402 830
-•
SB
1490
96.1
96.0
0.86
0.85
37
5.3
11
400
M3BM
400 LKD
3GBM
402 840
-•
SB
1491
96.3
96.3
0.87
0.85
42
5.4
12
450
M3BM
400 LKE
3GBM
402 850
-•
SB
1490
96.4
96.4
0.87
0.86
47
5.3
13
500
M3BM
450 LA
3GBM
452 510
-•
SB
1491
96.4
96.3
0.86
0.85
53
5.4
14
560
M3BM
450 LB
3GBM
452 520
-•
SB
1491
96.6
96.4
0.86
0.85
59
5.4
16