ABB
ABB DC Drives
16
3ADW000378R0101 |
DCS550 Technical catalog e a
Environmental conditions
System connection
Voltage, 3-phase:
230 to 525 V acc. to IEC 60038
Voltage deviation:
±10% continuous; ±15 % short-time *
Rated frequency:
50 Hz or 60 Hz
Static frequency deviation:
50 Hz ±2 %; 60 Hz
±2 %
Dynamic: frequency range:
50 Hz: ±5 Hz; 60 Hz: ± 5 Hz
df/dt:
17 % / s
* = 0.5 to 30 cycles.
Please note:
Special consideration must be given to voltage deviation in
regenerative mode.
Degree of protection
Converter module and options
(line chokes, fuse holder, field
supply unit, etc.):
IP 00
Paint finish
Converter module:
RAL 9002
Sound pressure level
Size
Sound pressure level LP (1 m distance)
Vibration
as module
enclosed conv.
as module
F1
55 dBA
68 dBA
0.5 g, 5...55 Hz
F2
55 dBA
72 dBA
F3
60 dBA
78 dBA
F4
66...70 dBA,
depending on fan
77 dBA
Environmental limit values
Permissible cooling air temperat.
- at converter module air inlet:
0 to +55°C
with rated DC current:
0 to +40°C
w. different DC current
+30 to +55°C
- Options:
0 to +40°C
Relative humidity (at 5...+40°C):
5 to 95 %, no condensation
Relative humidity (at 0...+5°C):
5 to 50 %, no condensation
Change of the ambient temp.:
< 0.5°C / minute
Storage temperature:
-40 to +55°C
Transport temperature:
-40 to +70°C
Pollution degree (IEC 60664-1, IEC
60439-1):
2
Site elevation
<1000 m above M.S.L.:
100%, without current reduction
>1000 m above M.S.L.:
with current reduction
Product compliance
– CE
– Low Voltage Directive 2006/95/EC — conformity EN61800-5-1 EN60146-1-1
– Machinery Directive 2006/42/EC — in cooperation EN60204-1
– EMC Directive 2004/108/EC — conformity EN61800-3
– Quality assurance system ISO 9001 and Environmental system ISO 14001
– RoHS
– C-Tick
– Pending: UL, cUL 508A or 508C and CSA C22.2 NO. 14-95, GOST R
EMC according to EN 61800-3 (2004)
– Categories C2, C3 or C4 with external EMC filtering or dedicated transformer